Home » Products » Lab Instrument Equipment » WH059X hydrogen sulfide in liquid sulfur determination machine » Hydrogen sulfide in liqued sulfide
Products
  • /upfile/2017/11/16/20171116154948_769.jpg
  • /upfile/2017/11/16/20171116160110_724.jpg
  • /upfile/2017/11/16/20171116160139_298.jpg
  • /upfile/2017/11/16/20171116160205_308.jpg

Hydrogen sulfide in liqued sulfide

GB/T2449.2-2015 Industrial Sulfide Section Two Liquid Productsprovided by the oil refinery gas, natural gas and other industrial liquid sulfur recovery prepared, or other processes for the production of liquid industrial sulfur needs to be measured in which the hydrogen sulfide and the mass fraction of hydrogen sulfide...

  • Summary
  • Performance characteristics
  • Technical Parameters
  • INQUIRY
Summary

《GB/T2449.2-2015 Industrial Sulfide Section Two Liquid Productsprovided by the oil refinery gas, natural gas and other industrial liquid sulfur recovery prepared, or other processes for the production of liquid industrial sulfur needs to be measured in which the hydrogen sulfide and the mass fraction of hydrogen sulfide, and provides a method for measuring hydrogen sulfide and hydrogen polysulfide.Actual there are many inconvenience in the implementation of the process at test center , such as no special oil bath for heating sulfur, no special use for blowing hydrogen sulfide gas path, making the site difficult to control.

For the inconvenience, designed WH059X hydrogen sulfide in liquid sulfur determination machine,and it can simultaneously test two samples or parallel sample test. Nitrogen flow rate can be adjusted automatically and automatic function after the user connection pipeline. It is automatically heating to blow the whole process and the use is very convenient.

WH059X hydrogen sulfide in liquid sulfur determination machine outline drawing as below


1 Air intake: connected to the nitrogen gas source and the nitrogen pressure: 0.2 ~ 1.0MPa.

2 Gas path 1:First nitrogen outlet flow, flow and screen display consistent.

3 Gas path 2:Second nitrogen outlet flow, flow and screen display consistent.

4 Control panel: Instrument control panel.

Performance characteristics

1.The structure is compact and small with integration design;

2. It can simultaneously carry on 2 sets of samples to test or to do the parallel test and also can carry on the test separately;

3. Using the unique PID constant temperature control principle and the temperature control precision is high;

4. Flow control is automatic and high accuracy;

5. Using the unique uniform oil bath heating, good uniformity and less oil.

Technical Parameters

1. Power supply100240VAC/50Hz

2. Power1500W

3. Temperature and precision of temperature control145℃±2℃

4. Nitrogen pressure0.21.0MPa

5. Nitrogen flow150 SCCM50300SCCM Can be set

6. Dimension380W×400D×180Hmm

INQUIRY